[{"@context":"https:\/\/schema.org\/","@type":"Article","@id":"https:\/\/www.gedeco.cz\/revize-elektroinstalace-v-kancelarskych-prostorach\/#Article","mainEntityOfPage":"https:\/\/www.gedeco.cz\/revize-elektroinstalace-v-kancelarskych-prostorach\/","headline":"Revize elektroinstalace v kancel\u00e1\u0159sk\u00fdch prostor\u00e1ch","name":"Revize elektroinstalace v kancel\u00e1\u0159sk\u00fdch prostor\u00e1ch","description":"Revize elektroinstalace a elektrick\u00fdch spot\u0159ebi\u010d\u016f jsou v kancel\u00e1\u0159sk\u00fdch prostor\u00e1ch v\u0161ech firem povinn\u00e9 ze z\u00e1kona. Je &hellip; <a href=\"https:\/\/www.gedeco.cz\/revize-elektroinstalace-v-kancelarskych-prostorach\/\" class=\"more-link\"><span class=\"more-button\">Pokra\u010dovat ve \u010dten\u00ed<span class=\"screen-reader-text\">Revize elektroinstalace v kancel\u00e1\u0159sk\u00fdch prostor\u00e1ch<\/span><\/span><\/a>","datePublished":"2026-08-05","dateModified":"2026-08-05","author":{"@type":"Person","@id":"https:\/\/www.gedeco.cz\/author\/#Person","name":"","url":"https:\/\/www.gedeco.cz\/author\/","identifier":1,"image":{"@type":"ImageObject","@id":"https:\/\/secure.gravatar.com\/avatar\/d693d76da4b3c2905ed32515295d3c5b2b37600a891f276917d3d592948bcc60?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d693d76da4b3c2905ed32515295d3c5b2b37600a891f276917d3d592948bcc60?s=96&d=mm&r=g","height":96,"width":96}},"publisher":{"@type":"Organization","name":"gedeco.cz","logo":{"@type":"ImageObject","@id":"\/logo.png","url":"\/logo.png","width":600,"height":60}},"image":{"@type":"ImageObject","@id":"https:\/\/www.gedeco.cz\/wp-content\/uploads\/pexels-ai25studioai-5853952_2.jpg","url":"https:\/\/www.gedeco.cz\/wp-content\/uploads\/pexels-ai25studioai-5853952_2.jpg","height":0,"width":0},"url":"https:\/\/www.gedeco.cz\/revize-elektroinstalace-v-kancelarskych-prostorach\/","about":["N\u00e1kupy"],"wordCount":415,"articleBody":"   Revize elektroinstalace a elektrick\u00fdch spot\u0159ebi\u010d\u016f jsou v kancel\u00e1\u0159sk\u00fdch prostor\u00e1ch v\u0161ech firem povinn\u00e9 ze z\u00e1kona. Je to zcela opr\u00e1vn\u011bn\u00fd a logick\u00fd krok, um\u00edte si p\u0159edstavit \u010delit nebezpe\u010d\u00ed z\u00e1sahu elektrick\u00fdm proudem, jemu\u017e budou vystaveni zam\u011bstnanci firmy \u010di jej\u00ed n\u00e1v\u0161t\u011bvn\u00edci, kdyby se tu revize neprov\u00e1d\u011bly? Revize nejsou povinn\u00e9 pouze v dom\u00e1cnostech, tam si za elektroinstalaci odpov\u00edd\u00e1 ka\u017ed\u00fd s\u00e1m za sebe, ale u firem je to jin\u00e1 situace, tam p\u0159ich\u00e1z\u00ed s elektroinstalac\u00ed a elektrick\u00fdmi spot\u0159ebi\u010di do p\u0159\u00edm\u00e9ho \u010di nep\u0159\u00edm\u00e9ho kontaktu mnoho lid\u00ed a \u0159e\u0161en\u00ed p\u0159\u00edpadn\u00fdch pr\u00e1vn\u00edch spor\u016f v p\u0159\u00edpad\u011b \u00faraz\u016f v\u010detn\u011b smrteln\u00fdch n\u00e1sledk\u016f a mo\u017en\u00fdch po\u017e\u00e1r\u016f budov by na\u0161e soudnictv\u00ed mohlo zcela zahltit.Povinn\u00e9 revize elektro v Praze technologie-budov.cz se tedy sna\u017e\u00ed tomuto jevu zabr\u00e1nit a sn\u00ed\u017eit riziko t\u011bchto ud\u00e1lost\u00ed na minimum. Revizn\u00ed pr\u00e1ce prov\u00e1d\u00ed kvalifikovan\u00fd a certifikovan\u00fd odborn\u00edk, elektrik\u00e1\u0159, kter\u00fd je pravideln\u011b p\u0159ezku\u0161ov\u00e1n ze znalosti pat\u0159i\u010dn\u00fdch p\u0159edpis\u016f. Revizn\u00ed pr\u00e1ce tedy nevykon\u00e1v\u00e1 \u017e\u00e1dn\u00fd amat\u00e9r a revize se tak\u00e9 neprov\u00e1d\u00ed pouze vizu\u00e1ln\u00ed formou, ale pomoc\u00ed m\u011b\u0159ic\u00edch p\u0159\u00edstroj\u016f.Jestli\u017ee elektrik\u00e1\u0159 \u2013 revizn\u00ed technik odhal\u00ed n\u011bjakou z\u00e1vadu, zaznamen\u00e1 ji do protokolu o revizi a upozorn\u00ed na ni i \u00fastn\u011b, p\u0159\u00edpadn\u011b navrhne vhodn\u00e9 \u0159e\u0161en\u00ed k n\u00e1prav\u011b situace. Elektrik\u00e1\u0159i se p\u0159i revizi \u0159\u00edd\u00ed tak\u00e9 tzv. Protokolem o ur\u010den\u00ed vn\u011bj\u0161\u00edch vliv\u016f, kter\u00e9 na elektroinstalaci a spot\u0159ebi\u010de v dan\u00e9m objektu p\u016fsob\u00ed. Protokol usnad\u0148uje orientaci v prost\u0159ed\u00ed a upozor\u0148uje na n\u011bkter\u00e9 nebezpe\u010dn\u00e9 jevy, kter\u00e9 mohou na elektrick\u00e1 za\u0159\u00edzen\u00ed a spot\u0159ebi\u010de m\u00edt negativn\u00ed vliv. Revizn\u00ed pr\u00e1ce v administrativn\u00edch budov\u00e1ch i jin\u00fdch objektech tak\u00e9 zahrnuj\u00ed revize nouzov\u00e9ho osv\u011btlen\u00ed, je-li zde p\u0159\u00edtomno, a pak tak\u00e9 revize hromosvod\u016f. Tato za\u0159\u00edzen\u00ed rovn\u011b\u017e mus\u00ed podl\u00e9hat revizn\u00edm, nouzov\u00e9 osv\u011btlen\u00ed v p\u0159\u00edpad\u011b v\u00fdpadku elektrick\u00e9ho proudu v budov\u011b s mnoha zam\u011bstnanci zaji\u0161\u0165uje jejich bezpe\u010dnou evakuaci a v p\u0159\u00edpad\u011b hromosvodu je jeho po\u0161kozen\u00ed velmi nebezpe\u010dn\u00e9 vzhledem k tomu, \u017ee i relativn\u011b m\u00edrn\u011b po\u0161kozen\u00fd hromosvod nezaji\u0161\u0165uje bezpe\u010dn\u00fd svod blesku do zem\u011b a je to podobn\u00e9, jako kdy\u017e v budov\u011b \u017e\u00e1dn\u00fd hromosvod nen\u00ed.                                                                                                                                                                                                                                                                                                                                                                                                  "},{"@context":"https:\/\/schema.org\/","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Revize elektroinstalace v kancel\u00e1\u0159sk\u00fdch prostor\u00e1ch","item":"https:\/\/www.gedeco.cz\/revize-elektroinstalace-v-kancelarskych-prostorach\/#breadcrumbitem"}]}]